Open-Structure Grating Monochromator – Fully visible optical path for intuitive understanding of dispersion principles
Dual Light Sources – 45° flip mirror for quick switching between mercury lamp (calibration) and LED (continuous scanning)
Continuously Tunable Wavelength – Breaks the 5-wavelength limitation, covering the visible spectrum
Innovative Opto-Mechanical Design: Ensures rapid optical path alignment and high positioning accuracy.
Precision Optical Breadboard – Standard mounting holes for flexible component placement and experiment expansion
Hierarchical Teaching Approach: Rich experiment contents support instructors in designing progressive, multi-level teaching activities.
Observing grating diffraction and understanding the principles of light dispersion
Wavelength calibration of the diffraction grating monochromator
Current-voltage characteristic curve measurement (with different wavelength monochromatic light)
Spectral response characteristic testing of the photocathode (continuous wavelength scanning)
Investigating the relationship between photocurrent and incident light intensity
Exploring the variation of stopping potential with incident light frequency
Feature | Traditional Filter-Based Apparatus (e.g., BEX-8504A) | Grating-Based Apparatus (BEX-8518) |
Dispersion Method | Mercury spectral lines + bandpass filters | Reflective diffraction grating monochromator |
Available Wavelengths | Only 5 discrete wavelengths (365nm/405nm/436nm/546nm/577 nm) | Continuously tunable wavelengths (covering visible range) |
Spectral Response Experiments | Not feasible (insufficient data points) | Full spectral response curve achievable |
Optical Path Visibility | Enclosed "black box" | Open optical path, principles fully visible |
Light Source System | Single mercury lamp | Mercury lamp + LED dual source system |
Wave-Particle Duality Verification | Particle nature only (photoelectric effect) | Both wave nature (grating diffraction) and particle nature (photoelectric effect) on a single apparatus |
Inquiry-Based Experiments | Limited | Supports design-oriented and inquiry-based experiments |
| No. | Part Name | Main Parameter |
| 1 | iToF Light Speed Measurement Controller | Capable of simultaneously conducting flight time and phase method for measuring the speed of light. |
| Flight time measurement and display with ps-level accuracy. | ||
| Supports both single-shot measurement and continuous measurement modes. | ||
| 2 | iToF Light Speed Measurement Laser Light Source | Light sources and light source platforms |
| 3 | Track | Length: 600mm |
| 4 | Overhead Gantry Assembly | Including sliding seat, reflective block, support rod, fixing screw and hand-tightening screw |
| 5 | Transparent Medium Block 1 | Size:300 * 28 * 40mm |
| 6 | Transparent Medium Block 2 | Size:400 * 28 * 40mm |
| 7 | Transparent Sink | Size:580 * 29 * 40mm |
| No. | Part Name | Model | Qty. |
| 1 | iToF Light Speed Measurement laser light source | BEM-5011 | 1 |
| 2 | iToF Light Speed Measurement Laser Light Source | BIM-6217 | 1 |
| 3 | Track | BEM-5201-06 | 1 |
| 4 | Overhead Gantry Assembly | Z010002T2 | 1 |
| 5 | Transparent Medium Block 1 | M060005T2 | 1 |
| 6 | Transparent Medium Block 2 | M060006T3 | 1 |
| 7 | Transparent Sink | M060008T2 | 1 |
| 8 | iToF Light Speed Measurement cable | C040004 | 1 |
| 9 | Plastic measuring cup | A070022 | 1 |
| 10 | BNC connecting Cable | BC-105076 | 2 |
| 11 | 8-Pin connecting Cable | BC-105077 | 2 |
| 12 | Power cord | BC-105075 | 1 |